TM70Bi V3.1 (03/09) 1121174.pdf
IKUSI reserves the right to change this information without prior notice.
CAN communication non
active
CAN controller disconnected
If the problem is associated with the equipment, please send both the transmitter and the receiver
to the your Technical Assistance Service Agent, together with a description of the problem and
the status of the LED’s.
If the transmitter becomes so damaged that a spare has to be arranged, it can be quickly
substituted by following the instructions in ANNEX A.
Display error messages V 2.4:
Inclinometer detected due to an incorrect position of the
transmitter
Crane selector is in wrong position after a crane has been
selected previously
Error when trying to access the content of the EEPROM or the
internal memory. The content of the EEPROM cannot be copied
into the internal memory
When duplicating EEPPROM modules a copy failure occured
during the new EEPROM updating process
Internal memory access failure
Error when writing EEPROM data into the flash memory or timeout
error occured when trying to access to the memory
Error when trying to close the internal memory access
The radio cannot be opened
Data cannot be written in the radio
When releasing the STOP pushbutton the signals and the masks
do not match indicating that some masked order is still activated.
Error when trying to open the range limiter
Range limiter data cannot be read
Kommentare zu diesen Handbüchern