TM70Bi V3.1 (03/09) 1121174.pdf
IKUSI reserves the right to change this information without prior notice.
9.5 - SIGNALLING
The receiver is furnished with two signalling LEDs, controlled according to CiA DR-303-3
recommendation:
CAN-RUN (green): indicates the system state inside the CANopen machine state:
- Blinking every 200 ms. In preoperational state.
- Solid green permanently in operational state.
- One blink every second in stop state.
CAN-ERR (red): indicates error if switched on; in normal conditions it must be switched off.
9.6 - TM70 CAN RECEIVERS
9.6.1 - Ref. 3302626 70GR902 RX-RCANNOCE / TECHNICAL SPECIFICATIONS:
70GR902 RX-RCANNOCE Ref. 3302626
Available frecuencies (ISM bands)
Power supply / Maximum consumption
Inputs / Outputs interface
CAN:Standard CAN Open protocol 401 (CIA DS401)
External: NEARSON S325TR-015 or equivalent
Working frequency selection
Automatic: LBT (listen before talking)
Long = 151mm / Width = 129mm (160mm with PG) /
Height = 61mm
MultiLED:
7 external LEDS (6 green + 1 bicoloured)
2 internal LEDS (CAN status: 1 red + 1 green)
Fast PLUG-IN plugs and 2 x M16 cable glands
1) Power supply cable gland: M16 / IP67
2) Inputs / Outputs interface cable gland: M16 / IP67
Cat. 1 EN-954-1 / 1 STOP relay: 250V / 6A maximum
STOP response time = 50 miliseconds
CAN BUS termination (120 Ohm)
ON / OFF jumper (internal)
Programmable: 0,5 to 2 seconds (máx)
Output protections (STOP)
Operating mode temperatura range
-20ºC / +70ºC (-4ºF / 158ºF)
Storage temperatura (24h)
-25ºC / +75ºC (-13ºF / 167ºF)
Storage temperature –long periods-
-25ºC / +55ºC (-13ºF / 131ºF)
TM70 range supported transmitters
T70/1/2; T70/3/4; T70/5/6; T70/7/8
Available complete systems
Ref. 3302XXX Equipo comp. TM70/X.CAN-C1-915
Kommentare zu diesen Handbüchern