TM70Bi V3.1 (03/09) 1121174.pdf
IKUSI reserves the right to change this information without prior notice.
OUTPUT 1 (VO1)
The connections of the output 1 are through 4 pole terminal plug, with the follow pin assignment:
Analogue output of channel 1
Zero position signal signal to get through the output 1 when the relay is inactive
OUTPUT 2 (VO2)
The connections of the output 1 are through 4 pole terminal plug, with the follow pin assignment:
Analogue output of channel 2
Zero position signal signal to get through the output 2 when the relay is inactive
ISP (PROGRAMACION “IN CIRCUIT” / “IN SYSTEM”)
The expansion has a connector to record “In-System” (eg. Microprocessor software update). This connector
has 10 pins:
Input connected to the ground to place the microcontroller in recording mode
Power supply output at 3,3 V
Reset input, active when it is connected to ground
Power supply output at 12 V (not stabilized, can vary between 8 y 22 V)