TM70/3-10 & i-Kontrol Console RC System
U035.3-TM70_Console_Sys
12
SIGNAL ONindicates the working frequency RF signal is being received.
DATA (When) ONindicates that received data is correctly formatted.
ID
ONindicates the receiver has recognized the transmitter identification
code.
CAN_RUN ONindicates that communications with CAN expansion boards are OK.
CAN_ERR OFF
4. STOP relays KSTOP1 and KSTOP2 will be activated. The K2/START relay is
energized when the Start button is pushed.
5. Press any Control function button; its corresponding relay should energize. In
case of an active function, the safety relay K1/SAFETY will also energize. Check
each control in this manner.
6. Turn off the transmitter using the STOP button. Check to make sure all of the
relays are de-energized and that the DATA, ID, and SIGNAL LEDs go out. At this
point, they behave as they do in SCANNING mode.
7. Reconnect power to the motors. Move to the usual working position. Check to
make sure that all Control functions and the STOP button are properly operating.
Note: Neither Cervis or Ikusi is responsible for incorrect installation of equipment,
interferences produced as a result of frequency collisions, or of the working frequencies in
fixed facilities where several radio remote systems share or have the ability to share the