Cervis TM70 Installationshandbuch Seite 72

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 103
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 71
TM70/3-10 & i-Kontrol Console RC System
U035.3-TM70_Console_Sys
64
21.0 INCAN Option
The INCAN interface provides a means to increase the number of analog and digital inputs for
the LR72 (up to N*5 + 1 where N = number of ICAN cards; maximum = 2 units).
Figure 42. INCAN Interface Block Diagram
Each INCAN interface can support a maximum of five (5) digital/analog micro-modules.
IN4D: four (4) digital inputs module (0-24VDC)
IN010V: analog Voltage input for 0-10VDC
9N0450P: Pulse Inputs for 0-450pps (for example, use with an anemometer)
A TM70 system can operate with a maximum of two (2) INCAN cards using the following
configurations:
40+(4) IN4D card directly connected to the LR72 max. 44 digital 0-24VDC inputs
10+ IN10V card directly connected to the LR72 max. 11 analog inputs (8-bit resolution)
10+ IN45P card directly connected to the LR72 max. 11 input pulse-signal counter (0-
450)