TM70/3-10 & i-Kontrol Console RC System
U035.3-TM70_Console_Sys
16.6 Working Zone
Note: Operating Mode for the following is as previously described in Heading 16.0.
The covered working zone can be circular (standard configuration) or elliptical (if required as an
option, opening the LEDs about ±20° per one direction D) for each LA70M or LA70M Ex
module.
16.6.1 Zone Coverage (Working Area)
All LEDs are assembled in parallel mode for infrared emission coverage of a Circular zone
(where D=d).
Figure 28: Working Area Example
LEDs are assembled in wide-assembly mode for infrared emission coverage of an Elliptical zone
(where D≠d).
Table 23: Working Area Dimensions for Circular and Elliptical Working Areas
h (ft.)
h (ft.)
D (ft.)
63°
20 7 7 20 23 7
26 10 10 26 30 10
33 13 13 33 39 13
40 13 13 39 46 13
46 16 16 46 52 16
52 20 20 52 59 20
59 20 20 59 69 20
66 – 115 23 23 66 75 23