TM70/3-10 & i-Kontrol Console RC System
U035.3-TM70_Console_Sys
Figure 19. TM70 Configuration and Navigation Buttons
Enter Configuration Mode
To enter the Configuration Mode, press the LCD70 ENTER key and then press the transmitter
START button. The UP and DOWN buttons allow menu navigation to select the
preferred software option, and they also allow value selection when a range of values is
available.
The ESCAPE button aborts any selected menu option, and it also allows return to an upper level
in the software menu.
14.4 Data Feedback Operating Mode
The Data Feedback mode can be performed through software or by change using a rotary
switch. Software selection, the default method, is performed using the UP and DOWN buttons
on the LCD panel. Hardware selection is performed by moving a particular switch as determined
on the technical datasheet provided with the system.
14.4.1 Multiple Returns/Multiple Feedback
The transmitter can process multiple feedback of two types of information, but only one type can
be displayed at a time.
1. CAN return + one direct input in the receiver. In this case, the receiver must have an analog
card (IN010V or IN0450P) or a digital card (IN4D) connected to the LR70 card. The INCAN
configuration is not allowed in this case. The receiver is a slave in the CAN bus.
2. INCAN board + one direct receiver input. In this case, any number of analog or digital cards
can be connected directly, or the INCAN expansion card can be used; the CAN return will
be disabled. The receiver is a master in the CAN bus.
Only systems using software revision 2.4.x support direct connect of the feedback signal to the
LR72 card. Regardless, use of the INCAN card option allows simultaneous system management
of several feedbacks using software revision 3.1.x or greater.
The user can select the feedback information to display through software or hardware. UP and
DOWN display buttons allow the user to sequentially scroll through the feedback information.
The priority order of feedback is:
1. Information corresponding to the card—IN 0-10 (2303755-10) or 0-450P (2303758-450P)—
directly connected to the receiver LR72 board.
2. Order for subsequent cards associated to the INCAN inputs depend on the order in which
they are connected – reading from low to high.
The INCAN file and parameters are configured and saved to the EEPROM.